1 Introduction
This manual describes the AnaGate models AnaGate CAN uno, AnaGate CAN duo and
AnaGate CAN quattro. The three devices essentially differ in the number of existing CAN
interfaces and are uniformly called "AnaGate CAN Gateway in the following, if it is not
necessary to differentiate.
1.1 Description
The AnaGate CAN Gateway connects a PC, a embedded PC or other general device to up
to four CAN busses via the TCP/IP network protocol. The AnaGate CAN Gateway basically
works as a CAN master with now own CAN identifier on the bus.
For this reason the AnaGate CAN uno provides an ethernet interface and a single electrically
isolated CAN interface. The AnaGate CAN duo provides an ethernet interface and two
independent electrically isolated CAN interfaces. The AnaGate CAN quattro provides an
ethernet interface and four independent electrically isolated CAN interfaces.
Controlling and configuration of a AnaGate CAN Gateway is made through TCP/IP. The
application protocol is described detailed in the document Manual AnaGate TCP/IP
communication. Thus the access to the device can be programmed via native calls to the
TCP/IP socket interface. This means that any communication partner with a LAN interface is
able to communicate to the device. Accessing the AnaGate CAN Gateway with the supplied
windows application library (DLL) is much comfortable and can be used with a conventional
programming language.
In bridge mode the AnaGate CAN Gateway can interconnect two physically independent
CAN networks via LAN/Ethernet (LAN bridge mode). The AnaGate CAN duo and AnaGate
CAN Quattro can additionally interconnect two internal CAN interfaces (internal bridge
mode). With the coupling over LAN/Ethernet is possible to connect separate CAN buses with
different baud rates over long distances.
1.2 Features
Supports CAN send and receive commands for all CAN devices on one, two or four
independent CAN interfaces
Variable CAN bus speed (10, 20, 50, 62.5, 100, 125, 250, 500, 800 or 1000 kbps)